TitleProduct

XXQ-3505 X-ray Flaw Detector

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Jiangsu

  • Validity to:

    Long-term effective

  • Last update:

    2017-12-20 14:39

  • Browse the number:

    37

Send an inquiries

Company Profile

Nanjing T-Bota Scietech Instruments & Equipment Co., Ltd.

By certification [File Integrity]

Contact:Ms. Rice Ding(Mr.)  

Email:

Telephone:

Area:Jiangsu

Address:Jiangsu

Website: http://t-bota.ledkingsun.com/

Product Details


X-ray Flaw Detector

1. General

The frequency-converted and gas-insulated X-Ray machine with ZY-2000 controller, is upgrading generation by NANJING T-BOTA SCIETECH INSTRUMENTS & EQUIPMENT CO.,LTD.
 
Portable X-ray machine is used to show the internal discontinuity or faults of materials, products or welding from a radiographic image on a film; can be used in the fields of ship-building, mechanical manufacturing, aviation, railroad, pressure vessel, boiler, petroleum, chemical and national defense, performing the non-destructive testing, especially at the construction site or high above the ground applications. Besides of its advantages of small size, light weight, easy to use, simple operation and self-troubleshooting, this machine has excellent performance of strongly interference-free capability, good working stability and operating reliability.
 
In this series of products, the X-ray generator is furnished with SF6 gas as an insulation, electric fan for forced cooling, the controller is equipped with the advanced microprocessor controlling system, SCR modules for voltage regulation, converting modules to control the primary and secondary side of the SCR as well as the advanced electronic circuits of voltage & current stabilization and interference-free .Thus, the performance of the complete equipment has been improved remarkly!
 
2.Technical Data 
Classify Model Tube voltage
(KV)
Capacity
(KW)
Focus Size
(mm)
Max. penetrate
A3 steel (mm)
 
Glass tube
Directional
40°
 
XXQ-1005 40-100 >1.0 1.0*1.0 8
XXQ-1605 60-160 >1.5 1.5*1.5 20
XXQ-2005 80-200 >2.0 1.5*1.5 29
XXQ-2505 130-250 >2.5 2.0*2.0 39
XXQ-3005 150-300 >3.0 2.5*2.5 49
XXQ-3505 250-350 >3.5 2.5*2.5 59
 
Glass tube
Panoramic
with flat
Target
360°*25°
XXH-1605 60-160 >1.5 1.0*2.0 18
XXH(GH)-2005 80-200 >2.0 1.0*2.4 26
XXH(GH)-2505 130-250 >2.5 1.0*2.4 36
XXH-3005 150-300 >3.0 1.0*3.4 46
XXH-3505 250-350 >3.5 1.0*3.4 56
 
Glass tube
panoramic
with cone
Target
360°*40°
XXHA-1005 40-100 >1.0 1.0*2.0 4
XXHA-1605 60-160 >1.5 1.0*2.5 15
XXHA-2005 80-200 >2.0 1.0*2.5 24
XXHA-2505 130-250 >2.5 1.0*2.5 34
XXHA-3005 150-300 >3.0 1.0*3.5 40
XXHA-3505 250-350 >3.5 1.0*3.5 50
 
 
Ceramic tube
Directional
 40°
XXG-1605 60-160 >1.5 1.5*1.5 20
XXG-2005 80-200 >2.0 1.5*1.5 29
XXG-2505 130-250 >2.5 2.0*2.0 39
XXG-3005 150-300 >3.0 2.5*2.5 49
XXG-3505 250-350 >3.5 2.5*2.5 59
Tube Current 5mA
Power Supply AC220V ±10% 50HZ
Controller Size 367×320×164(mm)
Insulating SF6 gas
Working
Temperature
-25°~ +40°
Humidity ≤85%
Standard Condition 1. Focus to Film : 600mm
2. Time of exposure :5min
3. Film :Kodak, intensified by double lead foil.
4. Treatment in the darkroom : temperature 20±2ºC, 5min ,Density ≥1.5
 Safe Pressure 0.35-0.50 MPa(Prohibition of use when it is lower than 0.35 MPa)